Brand Name |
Landcom |
Place of Origin |
Guangdong China (Mainland) |
Model Number |
NHC-450(C)/(J) |
Name: Medical equipment-High Frequency 500mA NHC-450 X-Ray Radiograph Technical Configurations 1) Main unit1. Function: It can be used for general X-ray chip shoot for all parts of body or for stretcher chip shoot.2. Characteristics:High frequency high pressure generator150kV/100kHz/630mA/50kW,with the function of operation information and faults indication and tube protection against overheatingSmall focus tube2) High frequency high pressure generator (CMP200 from CPI Canada)1.Control mode: compartment remote control. 8 parts of body is divided into 40 dissection sequences, and each of sequences is redivided into 3 choices of fat, middle and thin.2. Power50kW3. Frequency100kHz4. Output current range25500mA,step length 25mA5. Output voltage range40150kV,step 1kV6. Automatic exposure controlAEC generator has AEC control function(usable for ionization chamber)7. Exposure time range46000ms8. mAs rangebig focus 1.0600mAs,small focus 0.1100mAs9. According to chip shooting conditions, focus switch: focus switch automatically or manual switch.10.kV precision±5%11.mAs precision±10%+0.2mAs12.Minimum mAs0.1mAs3)Tube (from TOSHIBA)1. Powersmall focus22kW,big focus50kW2. Focus sizesmall focus 0.6mm,big focus 1.2mm3. Anode heat content150kHU4. Tube heat content1300kHU5. Anode rotary speed2850r.p.m6. Maximum voltage150kV7. Target angle12°4)Bed1. Bed surface2000mm×760mm2. Bed surface height700mm3. Longitudinal shift range of bed surface900mm4. Horizontal movement range of bed surface220mm5. Column longitudinal shift range2400mm6. Column rotary angle±180ºper 90ºcan be fixed7. Movement range of filter spool box stand560mm8. Distance of focus to film480-1200mmsternum stand selective9. Rotary angle of tube circling column-90º -+90ºtube can rotate freely, automatically lock10. Spool box photography equipment: manually install spool box)11. Spool box sizeless than 14"×17"12. Filter (Imported from Corea) grid rate101 grid density40L/cm focus1.1m5)Collimator Start time of collimator analog modulation30s6)Sternum Stand (selective) i.Filter (Imported) grid ratio 101 grid density 40L/cmii.Focus1.8m2. Up and down movement range700-1900mm3. Maximum spool box size14"×"174. Filter grid size:354mm×430mm(14"×"17)After sale service: We promise 1year warranty since delivery date. We'll supply you with a complete training of engineer about the application and maintenance and installation of products. The buyer is only responsible for the air ticket, board and room of our engineers if need to send our engineer to repair.